Brief Description
- The design of metal transparent material and breathing lamp perfectly combines technology and fashion ele- ments, making the instrument framework a new design language.
- The left and right symmetrical beam line design inside the column makes the flow path in a ring layout and has the storage function.
- The black surface material is resistant to conventional HPLC solvent corrosion.
- The "dark" array technology of light path is used to real- ize the automatic calibration of dark current.
- The automatic control of the lens switching mechanism and the dynamic variable slit device is realized by using the control circuit, which realizes the automatic real-time calibration of the data signal and improves the accuracy of the detection results.
- Through the highly integrated solvent switching system, the high-pressure binary can have the function of double high-pressure binary, even double four high-pressure, which makes the complex work simple.
- The automatic dilution and derivatization function of the autosampler makes the experiment easier.
- Use for ultra performance liquid chromatography.
- Use as the front end of mass spectrometry.
- The innovative double seal floating plunger and the motor driven cam drive plunger realize the accurate transmission of fluid.
- With the new drive control method, the infusion pulsation of the system is reduced and the durability and precision of the instrument are improved
- Intelligent high-precision cam detection device, ingenious design, reasonable layout, matching can simulate the actual working situ- ation of the push rod structure, improve and ensure the validity of detection data.
- Double contrast loop leakage sensor and perfect guide groove design make leakage alarm more accurate and timely.
Features
During the experiment, when the absorbance difference between AB and ab phases is large at the set wavelength, the baseline regular fluctuation is easy to appear in low proportion mixing. E3200 high pressure constant flow pump adopts patented pulsation damper and gradient mixer, which greatly reduces pulsation and improves mixing effect. Even at the limit ratio of 1:99, it has perfect baseline performance.
Easy to be sensitive and knows you better
It is often encountered in experiments that different analysis methods and different detection environments have different sensitivities. E3200 system's independent new detection pool, unique air duct system and micro step driver control the static angle of the unique technology, while achieving high precision, high sensitivity, low noise, low drift performance, so that the laboratory analysis work to achieve twice the result with half the effort.

Easy analysis and stable for quantitative
The data acquisition system adopts 24 bit high-precision AD conversion chip, with high data acquisition accuracy and wide linear range, up to 2.5AU, which can meet the requirements of high concentration and micro quantitative analysis at the same time. 0.1-50μL The injection volume reached R2= 0.9999, both in micro injection and large volume injection.